PUR98W Matte Black rangehood
Active Promotions
Benefits
Safety switch-off
Always on the safe side
Sensible, even in case of operating errors: the rangehood switches off automatically after 10 hours.
Stainless steel grease filters (10-layer)
Easy to use and effective against grease
Looks great and does a good job: effective grease filtering and easy cleaning in a dishwasher.
Specification
- Air throughput in Level 1 (m³/h) according to EN 61591
- 220
- Air throughput in Level 2 (m³/h) according to EN 61591
- 320
- Air throughput in Level 3 (m³/h) according to EN 61591
- 420
- Air throughput in Booster level (m³/h) according to EN 61591
- 470
- Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3
- 54.0
- Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3
- 66.0
- Noise level on Level 3 (dB(A) re 1 pW) according to EN 60704-3
- 71.0
- Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3
- 74.0
- Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13
- 47.0
- Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13
- 53.0
- Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13
- 61.0
- Sound pressure in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13
- 61.0
- Overall height for vented and external in in. (mm)
- 685
- Overall height for extraction mode and external mode rangehoods in mm
- 1005
- Overall height for recirculation in in. (mm)
- 815
- Overall height for recirculation mode rangehoods in mm
- 1135
- Canopy width in in. (mm)
- 898
- Canopy height in in. (mm)
- 62
- Depth of hood canopy in in. (mm)
- 500
- Net weight in kg
- 25.0
- Length of supply lead in m
- 1.5
- Standard plug fitted
- Total rated load in kW
- 0.304
- Voltage in V
- 230
- Fuse rating in A
- 10
- Frequency in Hz
- 50
- Number of phases
- 1
- Non-return flap
- Colour
- Matt black
- Number of dishwasher-safe stainless steel grease filters (10-ply)
- 3
- Number x W
- 3 x 3 W
- Light intensity in Lx
- 450 lx
- Colour temperature in K
- 3000 Kelvin
- Safety shut-off
- Extraction ducting connection at top
- Extraction connection at top and rear
- Diameter of extraction ducting connection in mm
- 150
- Telescopic chimney
- Dual-action blower
- AC motor
- Air throughput in Level 1 (m³/h) according to EN 61591
- 290
- Air throughput in Level 2 (m³/h) according to EN 61591
- 420
- Air throughput in Level 3 (m³/h) according to EN 61591
- 570
- Air throughput in Booster level (m³/h) according to EN 61591
- 790
- Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3
- 47.0
- Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3
- 54.0
- Noise level on Level 3 (dB(A) re 1 pW) according to EN 60704-3
- 62.0
- Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3
- 68.0
- Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13
- 34.0
- Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13
- 41.0
- Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13
- 41.0
- Sound pressure in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13
- 55.0