Compare
You have selected 1 items to compare.
Price |
$ 2,399.00
| ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Availability | In stock | ||||||||||||||||||||||||||
Ratings | (4)
| ||||||||||||||||||||||||||
Active promotion |
| ||||||||||||||||||||||||||
Accessories supplied | Non-return flap | Operating modes | Type of air guide Can be retrofitted Recirculation conversion kit (order separately) DUU 151 Active charcoal filter (order separately) DKF 19-P | Design | Colour Stainless steel | User convenience | Electronic controls Power levels (number without Booster level) 3 | Technical data | Canopy width in in. (mm) 884 Canopy height in in. (mm) 63 Depth of hood canopy in in. (mm) 297 Net weight in kg 13 Length of supply lead in m 1.5 Standard plug fitted Total rated load in kW 0.232 Voltage in V 230 Fuse rating in A 10 Frequency in Hz 50 Number of phases 1 | Installation notes | Extraction ducting connection at top Extraction connection at top and rear Diameter of extraction ducting connection in mm 150 | Blower | Dual-action blower AC motor | Extraction | Air throughput in Level 1 (m³/h) according to EN 61591 250 Air throughput in Level 2 (m³/h) according to EN 61591 300 Air throughput in Level 3 (m³/h) according to EN 61591 360 Air throughput in Booster level (m³/h) according to EN 61591 600 Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3 47 Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3 48 Noise level on Level 3 (dB(A) re 1 pW) according to EN 60704-3 52 Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3 64 Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13 31 Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13 34 Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13 38 Sound pressure in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13 50 | Construction type | Integrated extractor | Recirculation | Air throughput in Level 1 (m³/h) according to EN 61591 190 Air throughput in Level 2 (m³/h) according to EN 61591 250 Air throughput in Level 3 (m³/h) according to EN 61591 320 Air throughput in Booster level (m³/h) according to EN 61591 500 Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3 54 Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3 60 Noise level on Level 3 (dB(A) re 1 pW) according to EN 60704-3 64 Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3 72 Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13 39 Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13 45 Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13 49 Sound pressure in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13 57 | Filter system | Number of dishwasher-safe stainless steel grease filters (10-ply) 2 | Lighting | LED Number x W 4 x 3 W Light intensity in Lx 500 lx Colour temperature in K 3000 Kelvin | Safety | Safety shut-off | Cleaning convenience | Easy-to-clean canopy interior – CleanCover |
Remove product |